Indoor unit display codes and outdoor-linked faults for the split AC brands sold worldwide — from Asia to North America and Europe. Click a brand below to open its codes.

Jump to: LG · Samsung · Daikin · Voltas · Blue Star · Hitachi · Panasonic · Godrej · Whirlpool · Trane · Fujitsu General

Before you search: the same letter-number code can mean different things across a brand’s own model years. Treat the descriptions below as a strong first guess, then confirm against the sticker inside the indoor unit’s front panel or your model’s manual.
Safety first: burning smell, sparking, or a tripped breaker means a possible short circuit — cut power at the main board and call an electrician. Suspected gas leakage or refrigerant faults need a certified technician with proper equipment. See the full disclaimer before acting on any code.
LG
CodeLikely meaningWhat to check
CH 01Indoor unit fan motor malfunctionFan motor obstruction or wiring; often needs a technician if the fan doesn’t spin at all.
CH 02Indoor unit EEPROM (memory) errorIndoor PCB fault — usually needs PCB reset or replacement.
CH 04Outdoor unit compressor discharge protectionCheck outdoor unit airflow and refrigerant level isn’t low.
CH 05Communication error between indoor and outdoor unitInspect the connecting cable between units for damage or loose terminals.
CH 06Zero-cross detection error at the outdoor unitOutdoor PCB issue; usually not user-fixable.
CH 21Indoor and outdoor unit capacity mismatchConfirm the indoor and outdoor unit are a matched pair (post-repair swap issue).
E1Room temperature sensor open or short (older non-inverter models)Sensor connector may be loose behind the front panel.
CH 07Outdoor unit temperature sensor errorCheck the outdoor sensor connector and wiring.
CH 09Outdoor unit compressor overcurrentCheck outdoor unit ventilation and load on the compressor.
CH 10Outdoor unit EEPROM (memory) errorOutdoor PCB fault, usually needs board service.
CH 38Outdoor unit high pressure protectionClean the outdoor coil and check for restricted airflow.
Samsung
CodeLikely meaningWhat to check
E101Communication error between indoor and outdoor PCBCheck the inter-unit cable and both PCB connectors.
E162Outdoor temperature sensor errorSensor may be disconnected or damaged at the outdoor unit.
E181Indoor unit EEPROM errorIndoor PCB fault — typically needs replacement.
E201Indoor fan motor errorCheck for a jammed fan blade or failed motor.
E203Outdoor fan motor errorDebris around the outdoor fan, or motor winding failure.
E422Drain pump or float switch errorCheck the condensate drain line isn’t blocked.
E211Indoor unit EEPROM checksum errorIndoor PCB fault — usually needs board service.
E251Outdoor unit high pressure switch tripClean the outdoor coil and check airflow clearance.
E252Outdoor unit low pressure switch tripPossible refrigerant shortage — needs gauge check.
E469Outdoor unit compressor overcurrentCheck outdoor unit load and ventilation clearance.
Daikin
CodeLikely meaningWhat to check
U0Refrigerant shortage detectedPossible gas leak — needs a technician with gauges, not a DIY top-up.
U2Power supply voltage abnormalityCheck incoming voltage and connections at the isolator switch.
U4Communication error between indoor and outdoor unitInspect the interconnecting wiring for loose or corroded terminals.
A1Indoor PCB defectUsually requires indoor board replacement.
A6Indoor fan motor lock or overloadCheck for obstruction in the fan housing.
E5Compressor overload / thermal protection trippedCheck outdoor unit ventilation and clean the condenser coil.
E7Outdoor fan motor errorCheck for obstruction or motor failure at the outdoor fan.
H3High pressure switch activatedDirty outdoor coil or restricted airflow around the outdoor unit.
A9Electronic expansion valve abnormalityIndoor unit fault — needs technician diagnosis.
C4Indoor heat exchanger sensor errorCheck the indoor coil sensor connection.
C9Indoor suction air sensor errorCheck the suction air sensor wiring.
Voltas
CodeLikely meaningWhat to check
F1Indoor room temperature sensor errorSensor connector loose behind the indoor front panel.
F2Indoor coil temperature sensor errorCheck the coil sensor clip and wiring.
F3Outdoor coil temperature sensor errorSensor damage at the outdoor coil.
F4Outdoor discharge temperature sensor errorCompressor discharge sensor fault — technician required.
F5Communication error between indoor and outdoor unitCheck the connecting cable and terminal block.
F6EEPROM (memory) errorPCB fault, usually needs board service.
F8Overload or high-pressure protectionClean the outdoor condenser and check for blocked airflow.
F9Outdoor fan motor faultCheck the outdoor fan for obstruction or motor failure.
F0Refrigerant leak detectedNeeds a technician with gauges — do not attempt a DIY gas top-up.
F7Outdoor ambient temperature sensor errorCheck the outdoor ambient sensor connection.
Blue Star
CodeLikely meaningWhat to check
E1Indoor room temperature sensor errorSensor wiring loose inside the indoor unit.
E2Indoor coil sensor errorCheck the coil sensor position and connection.
E4Communication errorCheck the inter-unit cable between indoor and outdoor.
E7Outdoor unit general faultRequires technician inspection of the outdoor PCB.
P1High pressure protection trippedClean the outdoor coil and check for restricted airflow.
P4Compressor overload protectionCheck outdoor unit ventilation clearance.
E3EEPROM (memory) errorPCB fault, usually needs board service.
E5Outdoor sensor errorCheck outdoor sensor wiring and connector.
E8Compressor overcurrent protectionCheck outdoor unit load and ventilation clearance.
P2Low pressure protection trippedPossible refrigerant shortage — needs gauge check.
Hitachi (blink-pattern models)

Many Hitachi split ACs don’t show a text code — they blink the operation lamp a set number of times, then pause and repeat.

BlinksLikely meaningWhat to check
1Indoor unit PCB errorIndoor board fault, needs service.
2Indoor fan motor errorCheck for obstruction or a failed motor.
3Communication error between unitsInspect the connecting cable.
5Indoor coil sensor errorCheck coil sensor connection.
7Drain pump errorCheck the condensate drain for blockage.
4Outdoor unit EEPROM errorOutdoor PCB fault, usually needs board service.
6Outdoor fan motor errorCheck for obstruction or motor failure at the outdoor fan.
8Compressor overload protectionCheck outdoor unit ventilation and coil cleanliness.
9High pressure protectionClean the outdoor coil and check airflow clearance.
10Low pressure protectionPossible refrigerant shortage — needs gauge check.
Panasonic
CodeLikely meaningWhat to check
H11Communication error between indoor and outdoor unitCheck the interconnecting wiring.
H14Indoor temperature sensor errorSensor connector loose inside the indoor unit.
H15Compressor temperature sensor errorOutdoor sensor fault, needs technician.
H97Outdoor fan motor errorCheck for obstruction at the outdoor fan.
H99Outdoor unit PCB errorOutdoor board fault, needs service.
U04No communication between indoor and outdoor unitCheck the connecting cable and terminals.
H23Indoor coil sensor errorCheck the indoor coil sensor clip and connection.
F94Outdoor unit high pressure protectionClean the outdoor coil and check airflow clearance.
F95Outdoor unit low pressure protectionPossible refrigerant shortage — needs gauge check.
U02Power supply voltage synchronization errorCheck incoming voltage at the isolator switch.
Godrej
CodeLikely meaningWhat to check
E1Room temperature sensor errorCheck the sensor connector behind the front panel.
E2Coil temperature sensor errorCheck the coil sensor clip position.
E3Communication errorInspect the inter-unit cable.
E4Overload protection trippedCheck outdoor unit airflow and coil cleanliness.
E5EEPROM (memory) errorPCB fault, usually needs service.
E6Outdoor fan motor errorCheck for obstruction or motor failure at the outdoor fan.
E7Outdoor unit overload protectionCheck outdoor unit ventilation clearance.
E8High pressure protection trippedClean the outdoor coil and check for restricted airflow.
E9Low pressure protection trippedPossible refrigerant shortage — needs gauge check.
E10Outdoor unit PCB faultOutdoor board fault, needs service.
Whirlpool
CodeLikely meaningWhat to check
E1Room temperature sensor errorSensor wiring loose inside the indoor unit.
E2Coil temperature sensor errorCheck the coil sensor connection.
E4Overload tripCheck outdoor unit ventilation clearance.
E5Communication failure between unitsInspect the connecting cable.
E6Outdoor fan motor errorCheck for obstruction or motor failure at the outdoor fan.
E7High pressure protectionClean the outdoor coil and check airflow clearance.
E8Low pressure protectionPossible refrigerant shortage — needs gauge check.
E9Outdoor unit PCB faultOutdoor board fault, needs service.
E10Compressor overload protectionCheck outdoor unit ventilation clearance.
E11Refrigerant leak detectedNeeds a technician with gauges — not a DIY fix.
Trane (North America)
CodeLikely meaningWhat to check
E1High pressure protectionClean outdoor coil and check airflow clearance.
E2Low pressure protectionPossible refrigerant shortage — needs gauge check.
E3Indoor coil sensor errorCheck the indoor coil sensor connection.
E4Outdoor coil sensor errorCheck the outdoor coil sensor connection.
E5Compressor overload protectionCheck outdoor unit ventilation clearance.
E6Communication error between indoor and outdoor unitInspect the connecting cable and terminals.
E7Indoor fan motor errorCheck for obstruction or a failed motor.
E8Outdoor fan motor errorCheck for obstruction or motor failure at the outdoor fan.
E9EEPROM (memory) errorPCB fault, usually needs board service.
E10Power supply voltage abnormalityCheck incoming voltage and connections.
Fujitsu General (global)
CodeLikely meaningWhat to check
E1Indoor unit signal reception errorCheck remote control batteries and signal path.
E4Communication error between indoor and outdoor unitInspect the interconnecting wiring.
E5Compressor overcurrentCheck outdoor unit load and ventilation clearance.
E6Outdoor fan motor errorCheck for obstruction or motor failure.
E8Indoor fan motor errorCheck for obstruction or a failed motor.
E9Indoor unit EEPROM errorIndoor PCB fault, usually needs board service.
EAOutdoor unit operating mode conflictCheck for a mismatched or shared outdoor unit setting.
EEDrain pump / float switch errorCheck the condensate drain for blockage.
F3High pressure protectionClean the outdoor coil and check airflow clearance.
F0Refrigerant sensor abnormalityPossible refrigerant issue — needs technician check.